AS 1530.3:1999: Early Fire Hazard

fire test, external walling cladding, pre-finished metal products, air-conditioning filters, insulation materials, Early Fire Hazard, Fire Indices, Smoke Developed Index, Heat Evolved index, Spread of Flame Index, Ignitability index, BCA, Specification C1.10, Specification C1.12
Services
CSIRO will conduct a number of fire tests (ignitability, flame propagation, heat release and smoke release) in accordance with AS/NZS 1530.3-1999 on Materials provided by you.
Deliverables
CSIRO will provide you with a written report of the results of the Services which will describe the test method, test as carried out, observations, the data obtained, results and conclusions.
Application
  1. The Deliverables may only be used for your internal business purposes.
  2. Deliverables must not be used in advertising or endorsements, for the purposes of dispute resolution, or in connection with a prospectus or capital raising.
  3. If the Services are to verify that the Materials conform to a standard published by a recognised standards body (the “Standard”) and the Services verify such conformity, then you may use the Deliverables to demonstrate conformity with the Standard to other people, provided that:
    i) any statement you make regarding the results of the Services clearly sets out the results and identifies the relevant Standard; and
    ii) you reproduce or provide access to the Deliverables in full.
Materials (Specimen Requirements)
This section contains detailed information of the materials you are required to provide CSIRO to allow performance of these services.
Materials
You will provide CSIRO with ten (10) specimens of each product to be tested. Specimens for AS/NZS 1530.3 must measure 600mm long by 450-mm wide. Please contact CSIRO for specific instructions for products having varying shades and thickness, coatings applied to a substrate, filter foam materials, or seating.
Material Details
Number of Specimens: 10
Specimen Dimensions: 600mm (Height) x 450mm (Width)
This test requires effectively flat test samples, so for conduits/pipes/ducting, any ribbing in the ductwork would need to be either bent flat or removed, whichever is more practical.
Dangerous Goods Information
Please supply Safety Data Sheets for submitted specimens. If specimens contain dangerous substances, please discuss details with CSIRO's technical Contact prior to submission.
Return Instructions
The tests are destructive. Unless otherwise agreed, CSIRO will dispose of the Materials upon completion of testing
Location
Testing performed at the following location:
CSIRO Services - Infrastructure Technologies CSIRO STORE, Rear of 11 Julius Avenue (Building 53), Riverside Corporate Park, North Ryde NSW 2113, Australia.
Delivery Instructions
Deliver to: CSIRO Services - Infrastructure Technologies CSIRO STORE, Rear of 11 Julius Avenue (Building 53), Riverside Corporate Park, North Ryde NSW 2113, Australia.
Attn Technical Contact: Faustin Molina (Services, North Ryde)
Contact e-mail: faustin.molina@csiro.au
Contact phone: +610294905516
Fee (AUD)

The fee listed is in Australian Dollars and excludes GST.

Additional Expenses

The Fee is based upon successful product evaluation and verification. Any additional work required due to failures, product modifications, meetings and consultations will incur an additional fee which CSIRO will advise you in writing. CSIRO will obtain your authorisation prior to any re-evaluation or additional work. Any fees incurred in the return of samples will be met by you.

Payment Terms

The Fee will be invoiced on the Start Date. Any Additional Expenses will be invoiced when incurred.

NATA Accredited